all the benefits of liquid helium flow
without the liquid.

Address multiple noise sources:

  • VIBRATIONAL
  • MAGNETIC
  • ELECTRICAL
  • AUDIBLE
  • XUHV VACUUM LEVELS
  • TEMPERATURE STABILITY

ELIMINATE INTERFERENCE

STINGER™ NOISE CANCELLATION

ELIMINATE VIBRATION

•  under 10 nanometers of displacement at sample point

• lower vibration configurations also available 

ColdEdge’s STINGER™ provides the lowest vibration closed-cycle cryogenic system commercially available in the 2026 market.

REMOVE MAGNETIC NOISE

•  CCR expander 1.8+ meters away

•  the STINGER™ transfer line and cryostats use 316L stainless steel and high purity copper (titanium can replace 316, increased vacuum) as non-magnetic materials

ISOLATE ELECTRICAL PARTS

•  the STINGER™ flexible transfer line can be electrically isolated from the cryocooler body.

BLOCK AUDIBLE INTERFERENCE

•  the STINGER™ cryocooler body can be enclosed in an acoustic box to eliminate audible disturbances.

XUHV VACUUM LEVELS

• Cryostat bakeable to 200° C

• Titanium and high purity copper cryostats available

EXCELLENT TEMPERATURE CONTROL

Plug-and-Perform

HOW Stinger® WORKS:

A closed loop re-circulator moves helium gas through three stages to cool the sample space (separate from the cryocooler circuit).

> Gas flows through Stinger transfer line
to cool experimental cold head

> Used gas returns to cooler via transfer line

> Cooled gas exits to be re-circulated by pump

STINGER™ POWER SCALING

TECHNICAL SPECIFICATIONS

Wordpress Table Plugin

SYSTEM COMPONENT MAP

U

Variable length flexible transfer line

U

Control manifold with 10m gas line set

U

Helium Re-circulator (Oil Free)

U

isolated experimental space (cryostat)

U

Compressor for CCR (water or air cooled)

U

Option: rolling cart accessory, for easy movement between experiments/labs

STINGER™ Closed Cycle Refrigerator (CCR)

Full system includes the following:

  • STINGER™ Closed Cycle Refrigerator (CCR)
  • Compressor for CCR (water or air cooled)
  • Helium Re-circulator (oil free)
  • gas line set & head power cable for CCR
  • Control manifold to adjust system
  • Variable length flexible transfer line
  • Experimental space (cryostat)

TECHNICAL OPTIONS

COMPRESSOR:

water cooled, 200 or 380/400/480V 3 phase, 50/60Hz

RE-CIRCULATOR:

water cooled, 220/230V, 50/60Hz 1 phase or 3 phase

FLEXIBLE TRANSFER LINE:

1.8 m – 3 m length options

OPERATION:

nonstop (24/7)
in any device orientation

INSERT ANGLES:

straight (180°) or corner (90°)

CRYOSTAT:

interchangeable, and
compatibile with both ColdEdge and other major brand LHe flow cryostats

(Oxford, ST400, etc)

key Stinger™ System Features

Major Laboratory Benefits:

WIDE TEMPERATURE RANGES

•  enables 3.8 K – 800 K
directly at the sample point

all capacity measurement takes at far end of gas line, directly at sample mount

ELIMINATE VIBRATION

•  under 10 nanometers of displacement at sample point

• lower vibration configurations also available 

ColdEdge’s STINGER™ provides the lowest vibration closed-cycle cryogenic system commercially available in the 2026 market.

ELECTRICAL ISOLATION

•  the STINGER™ flexible transfer line can be electrically isolated from the cryocooler body.

XUHV VACUUM LEVELS

• Cryostat bakeable to 200° C

• Titanium and high purity copper cryostats available

LONG FLEXIBLE LINE

•  reduces vibrational interference
to <10 nm at sample point

•  custom lengths available:
1.8m or 3m (6 ft or 10 ft)

•  freedom for XYZ and rotational cryostat movement

REMOVE MAGNETIC NOISE

•  CCR expander 1.8+ meters away

•  the STINGER™ transfer line and cryostats use 316L stainless steel and high purity copper (titanium can replace 316, increased vacuum) as non-magnetic materials

MULTI-EXPERIMENT APPLICATIONS

•  plugs into a wide variety of experimental cryostats

•  increase lab productivity by testing more samples/spaces per system cooldown (~4.5 hours)

• compatible with most pre-existing major brand LHe flow cryostats

COMPLETELY CLOSED CYCLE COOLING

•  system can run 24/7 all year long

•  continuous operation without liquid Helium top-offs

•  converts multiple open-flow cryostats to a recirculating system

REMOVE AUDIBLE SOUND

•  the STINGER™ cryocooler body can be enclosed in an acoustic box to eliminate audible disturbances.

• noisy compressors can be remoted located up to 20 meters away

ADAPTIVE LAB PLACEMENT

•  the STINGER™ body works in any orientation, even upside down!

•  small lab footprint – no more planning around LHe refills, Dewar tanks, and floor space

•  automatic operation offered

•  moves the cryocooler machinery off-table/off-chamber and away from experiment workspace

 

EXCELLENT TEMPERATURE CONTROL

ONE SYSTEM TO ADDRESS MULTIPLE SOURCES OF NOISE

VIBRATIONAL interference

MAGNETIC interference

ELECTRICAL interference

AUDIBLE interference

XUHV VACUUM LEVELS

TEMPERATURE INSTABILITY

Ready to get started?

tell us about your project

Via Email

This is the fastest way to schedule a no-pressure discussion meeting. If you’re unsure about equipment options, we’ll help clarify your needs and provide insight on best-use-case layout.

Contact us anytime at [email protected] with the details of your experimental setup!

In Person

ColdEdge exhibits at a large variety of physics, quantum, and science conferences over the year. We also host travel demonstrations at research labs around the globe, so users can see first-hand how our equipment performs.

To check when we’ll be in your area, visit the ABOUT page for ColdEdge’s 2026 calendar of events. We love to chat and sketch on napkins with fellow mad scientists.

Via Distributor

ColdEdge has partnered with local sales teams around the globe, to help with international project planning. To see which organization assists your area, please visit our Distributors Page for a full list of contact details.

By Phone

The ColdEdge office is open Monday-Friday, 9am-5pm EST

Please call +1 (610) 628 6363 to speak with our front desk.